Cast Iron AC Induction Motors – Mounting Bolt Torque Guidance

Last updated 5 days ago

The correct tightening torque depends on the motor frame size and the corresponding foot mounting bolt. Below is a general guideline based on typical ISO metric bolts used in our cast iron range:

Frame Size Mounting Bolt Size Recommended Torque (Dry)
80 – 90 M8 25 Nm
100 – 132 M10 49 Nm
160 – 180 M12 85 Nm
200 – 225 M16 210 Nm
250 – 280 M20 410 Nm
315 – 355 M24 710 Nm

 

  • Torque values are based on ISO grade 8.8 bolts with dry (unlubricated) threads. For lubricated threads, reduce torque by approximately 15–20%.
  • Flat washers are recommended to distribute load and prevent paint damage to motor feet.
  • Always ensure the mounting surface is flat and clean to avoid distortion during tightening.
  • For flange-mounted motors (e.g. B5), refer to flange mounting torque specifications.
  • Use of torque-controlled tools is advised. Avoid overtightening with impact drivers.
  • Bolt sizes may vary slightly depending on customer specification—refer to the motor’s dimensional drawing for exact details.